RV 80 Plus installation Kit K-RV-80-02
RV 80 BOARD with MONITOR – 40amp, DC/DC, Solar and 240volt.
Key features:
- Reliable Performance: The ePOWER Low Battery Cutoff safeguards batteries from non-essential discharges, ensuring engine starting power and protecting connected appliances from overvoltage.
- Microprocessor Control: Features 10 programs to manage voltage load engagement or disengagement across various voltage parameters.
- Safety Features: Includes overvoltage protection, ignition proof design (no relay, no spark), delayed alarm output, and delayed load disconnect.
- Versatile Applications: Suitable for recreational vehicles, service vehicles, and marine equipment.
- Easy Installation: Designed for easy assembly with provided wiring and mounting instructions.
High Output: Provides 40A to 50A output with a 775W power rating, selectable battery types (Gel, AGM, Flooded, Lithium, Program).
Charging Control: Features four-stage charging (Bulk/Absorption/Float/Maintenance) and supports a variety of battery types.
Input and Efficiency: Accepts wide input voltage ranges (90 to 265 VAC), power factor correction, and 82% charger efficiency.
Protection and Features: Equipped with reverse polarity, overcharge, over temperature, and output short circuit protection, with forced air ventilation.
Environmental Specs: Operates in temperatures from -20° to 60°C, with IP32 ingress protection and includes an LCD display for monitoring charging status.
Comprehensive Kits: Enerdrive’s RV Installation Kits are designed for 4WD canopies, caravans, camper trailers, commercial work vehicles, and more.
Versatile Layouts: Multiple layouts available to fit nearly every application, suitable for DIY handymen and professionals.
Pre-Wired for Simplicity: Kits are pre-wired where possible, with full wiring diagrams included for easy installation.
Durable Construction: Mounted on a 12mm black plastic board that is water and rot-resistant.
Service and Support: Enerdrive offers comprehensive service and support, with detailed knowledge of each kit’s layout and wiring.
Ouput Rating |
|
Output Voltage |
12V Nominal (8.0V min) |
Output Current (Maximum) |
40A – 50A |
Output power |
775W |
Charger DC Output (CH1): |
|
Selectable Battery Type |
Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range |
13.8V – 15.5V |
Float Voltage Range |
13.0V – 13.8V |
Charger Current (User Selectable) |
5/10/15/20/25/30/35/40/45/50A (default 40A) |
Equalize Voltage (flooded Battery) |
15.5V |
Equalize Charging Current |
10% of Bulk Current Setting |
Charging Control |
2 stage / 3 stage selectable (Default 3 stage) |
DC Output Bank |
Single |
Current draw from CH1 when in use |
= 50mA |
Battery Temperature Setting |
Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency |
95% |
Input Rating (CH2 – MPPT Solar) |
|
Input Voltage |
14.5 – 45VOC |
Maximum Input |
≤23 input, 500W (600W allowable) ≥37.5-45V input, 750W (800W allowable) |
Input Rating (CH3 – Start/Alternator) |
|
Input Voltage |
10.5 – 16VDC / 21 – 32DC |
Dimensions |
|
Height x Width x Depth |
242mm x 172mm x 74mm |
Unit Weight |
1.85 Kg |
Shipping Weight |
2.17 Kg |
EN31240-
Model |
EN31220 |
EN31240 |
EN31260 |
EN32430 |
CHARGER OUTPUT |
||||
Output Current (Maximum) |
20A |
40A |
60A |
30A |
OUTPUT VOLTAGE RANGE |
||||
Charge |
14.2 – 15.5 V |
28.4 – 31.0V |
||
Float |
13.4 – 13.8 V |
26.8 – 27.6V |
||
– Equalize |
16.0 V |
32.0V |
||
Charging Control |
Four stages (Bulk/Absorption/Float/Maintenance) |
|||
Two stages (Bulk/Absorption) |
||||
Constant Power Supply (Program setting) |
||||
Priority Battery Bank Charging |
||||
DC Output Bank |
Three (1 fully independent, 2 common with diode isolation) |
|||
Selectable Battery Type |
Gel, AGM, Flooded, Lithium, Program |
|||
Standby Current |
2 mA |
|||
CHARGER INPUT |
||||
AC Input Voltage (Nominal) |
90 to 265 VAC |
|||
AC Input Operating Range |
207-265 Vac (2.0 A Max)90-125 Vac (3.8 A Max) |
207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) |
207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) |
207-265 Vac (5.9 A Max)90-125 Vac (11.3 A Max) |
AC Input Frequency Range |
47 – 63 Hz |
|||
Power Consumption |
350W (Full Load) |
700W (Full Load) |
1050W (Full Load) |
1050W (Full Load) |
Power Factor Correction |
Yes |
|||
Charger Efficiency |
82% |
|||
PROTECTION AND FEATURES |
||||
Reverse Polarity |
Yes, (with user replaceable fuse/s) |
|||
Over Charge |
Yes, unit shutdown |
|||
Over Temperature |
Yes, unit de-rated and shutdown |
|||
Output Short Circuit |
Yes, (with user replaceable fuse/s) |
|||
Cooling |
Forced air ventilation (thermo controlled fan) |
|||
Temperature Setting |
Hot, Normal, Cold (no sensor connected) |
|||
Battery Temp Sensor Port |
RJ12 (standard battery temp. sensor supplied) |
|||
DISPLAY |
||||
LCD Display (with back light) |
Charging status, Battery Voltage, Output Current and Fault Codes. |
|||
AC INPUT AND DC OUTPUT CONNECTION |
||||
AC Input Connection |
IEC with Supplied 1.2M Power Lead |
|||
DC Output Connection |
Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread |
|||
DC Output Ground |
Single Heavy Duty Common Ground Stud |
|||
ENVIRONMENTAL AND OPERATING TEMPERATURE |
||||
Storage Range |
-40° to 70° C |
|||
Operating Range |
-20° to 60° C |
|||
Humidity |
5-95%, relative humidity non-condensing |
|||
Ingress Protection |
IP32 (Basic drip proof in vertical orientation) |
|||
Base Unit Weight and Dimensions |
||||
Weight: (kg) |
2.4 |
2.6 |
4.0 |
4.0 |
Dimension: (mm) L x W x H |
295 x 206 x 86 |
295 x 206 x 86 |
356 x 206 x 99 |
356 x 206 x 99 |
Optional Accessories |
Remote Digital Display / Enerdrive Part Number EN3REM |
|||
Regulatory Compliance |
Complies with AS/NZS 60335.2.29 Including Australian deviations. |